welcome to Haiyuan water treatment Co. Ltd English|Spainsh|Online message
> Blog

The current position:Home > Blog

  • Notes about Reverse Osmosis Equipment

                HYWATER         Reverse Osmosis plant/system

    Notes about Reverse Osmosis EquipmentWith the wide application of water purification equipment in different industries, the scope of application of reverse osmosis membranes has also increased. The reverse osmosis equipment has high filtration accuracy so cam completely filter out the pollutants in drinking water, so t···
    Read More
  • How to select Solenoid valve in Water treatment plant

                HYWATER         Water filtration system

    How to select Solenoid valve in Water treatment plantSolenoid valve is an automatic basic component used to control the direction of fluid, belonging to the actuator; usually used in mechanical control and industrial valves, to control the switch of valve. Working principleThere is a closed cavity in the solenoid ···
    Read More
  • Why Ultrafiltration system can not be used to Desalinate water

                HYWATER         Water filtration system

    Why Ultrafiltration system can not be used to Desalinate water Ultrafiltration system membrane has a strong filtration performance, thus mainly be used to intercept harmful substances in water, while keeping the pH value of product water unchanged. Ultrafiltration can effectively remove large proteins, bacteria an···
    Read More
  • Precautions about Installation of Reverse osmosis equipment

                HYWATER         Reverse Osmosis plant/system

    Precautions about Installation of Reverse osmosis equipment The installation of Reverse osmosis equipment mainly is the installation of membrane elements and the connection of pipes. When loading membrane element, suggest to use some lubricating material to the section with the sealing ring to make it more conveni···
    Read More
  • Notes about UF Water Treatment Plant

                HYWATER         Water filtration system

    Notes about UF Water Treatment Plant1) Membrane filtration method: It means that substances larger than the pore size of the membrane are trapped on the surface of the membrane, and only substances smaller than the pore size of the membrane can pass through the membrane, and there is a method for clear separation ···
    Read More
  • Why add inhibitor dosing for Reverse osmosis system

                HYWATER         Reverse Osmosis plant/system

    Why add inhibitor dosing for Reverse osmosis systemBefore talking about the role of reverse osmosis inhibitor dosing, reverse osmosis system passes raw water through precision filters, granular activated carbon filters, compressed activated carbon filters, etc., and then passes through The pump is pressurized, and the ···
    Read More
  • 20 Quick notes about Water treatment plant

                HYWATER         Water filtration system

    20 Quick notes about Water treatment plant1. The activated carbon filter mainly adsorbs (organic matter) and (residual chlorine) in water.2. Combined use of strong and weak base resin, weak anion resin exchange strong acid ion, strong anion resin exchange (weak acid ion).3. The filling ratio of mixed bed anion and cati···
    Read More
  • Correct operation methods of RO plant

                HYWATER         Reverse Osmosis plant/system

    Correct operation methods of RO plantSteps need to be noticed when install the new RO membrane of RO plant1. First, backwash and rinse the quartz sand and active carbon to make then clean2. Detect if any residual chlorin in water that may oxidize the membrane. If the residual chlorine exceeds the standard, it need to s···
    Read More
  • How to adjust Pressure switch of RO plant

                HYWATER         Reverse Osmosis plant/system

    How to adjust Pressure switch of RO plantHigh/low pressure switchThe high/low pressure switch of RO plant is to prevent the high pressure pump from working under extreme high/low pressure. With the increase of operation time, the membrane will be blocked so pressure will increase steadily. If the pressure increase···
    Read More
  • Pretreatment methods in Water treatment plant

                HYWATER         Water filtration system

    Pretreatment methods in Water treatment plant1) Air flotationAir flotation algae removal is to supply dissolved air water from the dissolved air system, and the algae in the water are adhered to the water by the bubbles in the water, so that they float on the surface of the pool, and are scraped off with a slag sc···
    Read More
  • Information about UF treatment plant

                HYWATER         Water filtration system

    Information about UF treatment plant In the field of water treatment, UF treatment plant is efficient in filtering impurities, and its filtration accuracy can reach 99.99%, which can effectively remove most of the harmful substances in water; and use little or no use Chemical agents can effectively avoid secondary···
    Read More
  • Common failures of Reverse osmosis systems

                HYWATER         Reverse Osmosis plant/system

    Common failures of Reverse osmosis systems Before using the reverse osmosis system, first need to check whether the appearance of the machine is normal. After confirming that everything is normal, then connect the water source and power supply. If the operation fails, find out the problem and solve it immediately.···
    Read More
©2121 HY water, Ltd All Rights reserved.
Industrial & drinking Reverse osmosis water purification system,Seawater desalinaton plant in Africa, Asia, Europe, South America, Australia |Made in China by Haiyuan. an ISO9001:2019 Certified Company Add: Xiansha Gaobu Town,Dongguan city,Guangdong,China|+86(769)88706055| Email:sales@seawaterroplants.com
HaiyuanHaiyuanHaiyuan
Need Help? Chat with us
haiyuan