welcome to Haiyuan water treatment Co. Ltd English|Spainsh|Online message
> Blog

The current position:Home > Blog

  • The solution to the resin being flushed out during Water softener regeneration

                HYWATER         Reverse Osmosis plant/system

    The solution to the resin being flushed out during Water softener regenerationIn the operation of Water softener equipment, it is often seen that the softened resin runs into the sewer or the water tank, resulting in waste of resin and unqualified softened water. Let's analyze the occurrence and solution of this pr···
    Read More
  • Installation of reverse osmosis system membrane elements

                HYWATER         Reverse Osmosis plant/system

    Installation of reverse osmosis system membrane elementsPreparation before installation1) When passing the pretreated water to the reverse osmosis system, it is necessary to ensure that there are no impurities such as dust, grease, and metal residues in the pipeline system and pressure vessel, so as to prevent the memb···
    Read More
  • Leak detection methods for RO water treatment equipment

                HYWATER         Reverse Osmosis plant/system

    Leak detection methods for RO water treatment equipment Soap methodSoap method is a very common method. Apply a certain pressure to the test object and apply soapy liquid to the outside. If there is leakage, air bubbles will be generated. According to the soap liquid detection method, gas pressure is used to deter···
    Read More
  • Common knowledge about RO plant

                HYWATER         Reverse Osmosis plant/system

    Common knowledge about RO plant Unit conversion of the size and water flow of Reverse osmosis membraneIn the water treatment process, the unit of length is generally mm (in=inch, ft=foot): 1in=25.4mm, 1ft=304.8mm, 12in=1ftReverse osmosis membrane aperture: 10-6in=2.54x10-6mmArea: 1ft2=144in2 =929x10-4m²=92903mm²···
    Read More
  • About Ultraviolet Sterilizer be used in Water Treatment Plant

                HYWATER         Water filtration system

    About Ultraviolet Sterilizer be used in Water Treatment Plant Advantages of Ultraviolet sterilizer be used in Water Treatment Plant 1) Ultraviolet disinfection technology has high sterilization efficiency and safe and reliable operation. Ultraviolet disinfection has high inactivation efficiency for bacte···
    Read More
  • Installation Info about Water Softening Equipment

                HYWATER         Water softener

    Installation Info about Water Softening EquipmentThe conditions that need to be met for the installation of large-scale Water Softening Equipment are as follows: 1. The hardness of the source water is ≤8mmol/L (if the hardness of the source water is greater than 8mmol/L, it needs to be redesigned); 2. The eq···
    Read More
  • Tips about Water softening equipment

                HYWATER         Water softener

    Tips about Water softening equipmentIn daily life, we often see that scale will form on the inner wall of the kettle after a long time, because the usual domestic water contains inorganic salts, such as calcium and magnesium salts. These salts cannot be found by the naked eye in water at room temperature. Once they are···
    Read More
  • Adverse effects of high water temperature on Water treatment equipment

                HYWATER         Reverse Osmosis plant/system

    Adverse effects of high water temperature on Water treatment equipmentIn the high temperature environment, the performance of the reverse osmosis membrane of ultrapure water treatment equipment will be greatly negatively affected. When the water temperature increases, the desalination rate of the reverse osmosis membra···
    Read More
  • Reverse osmosis membrane plant Inlet water quality requirements

                HYWATER         Reverse Osmosis plant/system

    Reverse osmosis membrane plant Inlet water quality requirementsWhen designing professional reverse osmosis membrane plant for users, the source water sample need to be tested to check water quality first, then can better design reverse osmosis membrane plant to fit the needs of customers.  Reverse osmosis membrane···
    Read More
  • How to reduce the operating cost of Reverse Osmosis machine?

                HYWATER         Reverse Osmosis plant/system

    How to reduce the operating cost of Reverse Osmosis machine?1️⃣The quality of the inlet water is related to the service life of the consumables of the machinery. Therefore, the water quality of the inlet water must be similar to the water report you send, otherwise, the frequency of replacement of spare parts wi···
    Read More
  • Common question about Reverse Osmosis Equipment

                HYWATER         Reverse Osmosis plant/system

    Common question about Reverse Osmosis Equipment1) Why does the sealing ring in the reverse osmosis equipment expand?In order to achieve the sealing and isolation of each section in the membrane shell of the reverse osmosis equipment, a sealing rubber ring should be used in the membrane shell to reduce the installation ···
    Read More
  • Máquina desionizada 500LPH RO+EDI para piezas de limpieza del cliente (Requisito del cliente: agua tratada: 10Ω)

                HYWATER         Deionized Water System

    Máquina desionizada 500LPH RO+EDI para piezas de limpieza del cliente (Requisito del cliente: agua tratada: 10Ω)  1- El agua tratada también se llama agua desionizada, entonces, ¿por qué necesita este tipo de agua?       Generalmente, el agua contiene demasiados iones de calcio, magne···
    Read More
©2121 HY water, Ltd All Rights reserved.
Industrial & drinking Reverse osmosis water purification system,Seawater desalinaton plant in Africa, Asia, Europe, South America, Australia |Made in China by Haiyuan. an ISO9001:2019 Certified Company Add: Xiansha Gaobu Town,Dongguan city,Guangdong,China|+86(769)88706055| Email:sales@seawaterroplants.com
HaiyuanHaiyuanHaiyuan
Need Help? Chat with us
haiyuan