Industrial water deionizer,water deionizer
Deionized water: Deionized water prepared by non-heat treatment using ion exchange method, reverse osmosis method, ultrafiltration method, EDI electric desalination method. That is, deionized water refers to pure water after removing impurities in the form of ions. Deionized water is commonly referred to as "ultra-pure water" or "18 megohm water" in the semiconductor industry.
A: Industrial water deionizer processe flow
Raw Water pump--> Multimedia Filter--> Activated Carbon Filter-->Security filter -->Cation exchange- Anion exchange-> Mixed-Bed Deionizer--> Deionized Water
B: Water deionizer configuration list
No | Items | Description | Remarks |
1 | Feed water tank | 10000L SS304 or PE | Client prepare |
2 | Feed water pump | CHL30-40/ SS304 | CNP/CHINA |
3 | Multimedia Filter | 1800*3000mm SS304 | HY/CHINA |
4 | Active carbon filter | 1800*3000mm SS304 | HY/CHINA |
5 | 20um PP filter | 40’"Φ350*H1000mm SS304 17pcs | HY/CHINA |
6 | Cation bed | Φ1800*3000mm Carbon steel Resin type:C100E Alkali tank:1000L | HY/CHINA |
7 | Anion bed | Φ1800*3000mm Carbon steel Resin type:A600 Alkali tank:1000L | HY/CHINA |
8 | Mixed-Bed Deionizer | Φ1800*4100mm Carbon steel Resin type:PPC100 Resin type:PFA400 Alkali tank:1000L*2 | HY/CHINA |
9 | 0.2um PP filter | 40" Φ350*H1000mm SS304 17pcs | HY/CHINA |
10 | 0.1um PP filter | 40’ Φ350*H1000mm | HY/CHINA |
11 | Pure water tank | 10000L SS304 | Client prepare |
Why need to provide the source water quality report?
1.The source water quality report can help engineers better understand the parameters of various indicators n the raw water, like the amount of all kinds of ions, bacteria, etc. Provide feasibility solution based on various parameter of raw water.
2. TDS(Total dissolved solid) and residual chlorine value is very import. before designing the proposal, engineers select high different pressure pumps with different pressures based on TDS value to make sure that the system can produce the clean water normally. Select the appropriate stainless steel material based on the residual chlorine to avoid the water leakage caused by corrosion.
3.From water analysis report can see the iron and manganese, turbidity, bacteria whether exceed the standard. Engineers can design the process flow chart and solution which best fit the demand to help reduce unnecessary expense which can help customers save the cost.
4. Engineers design the Industrial water deionizer suitable proposal based on raw water quality report and product water purpose/standard which can operate normally and best fit the customer demand.
BTW: If source water is municipal tap water or clean reservoir water or spring water no need report.
But please inform us the water characteristic.
Please contact us!