Wechat/Whatsapp:
+8613798883773
Deionized water treatment plant,Deionized treatment,di water
A: Deionized water treatment plant product description
Deionized water: Deionized water prepared by non-heat treatment using ion exchange method, reverse osmosis method, ultrafiltration method, EDI electric desalination method. That is, deionized water refers to pure water after removing impurities in the form of ions.
B: Deionized water treatment processe flow
Raw water → Multi-media filter → Activated carbon filter → Precision filter → Reverse osmosis equipment → Electric deionization (EDI) → Ultrapure water tank → Ultrapure water pump → Rear security filter → Water point
C: DI water configuration list
NO | The product name | Specifications | Quantity |
1 | The feed water tank | V=2m3 | 1set |
Liquid level Sensors | 1set | ||
2 | Raw water pump | Q=4m3/h H=40m SUS304 | 1set |
3 | Multi-media filter vessel | Model:1665 | 1set |
Size: Φ400×H1650mm | |||
Tank Material: FRP | |||
Control valve | 1set | ||
Multi-media filter:quartz sand | 100kg | ||
Pressure gauge:1MPA | 1set | ||
4 | Active carbon filter
| Model:1665 | 1set |
Size: Φ400×H1650mm | |||
Tank Material: FRP | |||
Control valve | 1set | ||
Multi-media filter: Active carbon | 50kg | ||
Pressure gauge:1MPA | 1set | ||
5 |
Water softener filter | Model:1665 | 1set |
Size: Φ400×H1650mm | |||
Tank Material: FRP | |||
Control valve | 1set | ||
Multi-media filter:Ion exchange resin | 50L | ||
Pressure gauge:1MPA | 1set | ||
6 | Cartridge filter& PP sediment filter | Size: 195*500*5 | 1set |
Material Stainless steel | |||
5um PP elements 20″ | 5set | ||
7 | One-high press pump | Q=4m3/h H=110m SUS304 | 1set |
8 | One stage reverse osmosis system | Pressure vessel:4040×1 | 5set |
RO membrane:4040 | 5set | ||
Pure water flow meter | 1set | ||
Concentrated water flow meter | 1set | ||
Concentrated water control valve | 1set | ||
Pipe valves | 1set | ||
High and low pressure protection switch | 1set | ||
Check valve | 1set | ||
Automatic cleaning valve | 1set | ||
Online monitoring of inlet conductivity of the water meter | 1set | ||
Online monitoring of production water conductivity meter | 1set | ||
Pressure gauge:0~0.7 | 2set | ||
Pressure gauge:0~2.5MPa | 2set | ||
Sampling valve | 1set | ||
9 | PH adjustable system | Burkert | 1set |
PE-40L | |||
10 | RO tank | V=1m3 SUS304 or PE | 1set |
Liquid level Sensors | 1set | ||
11 | EDI Booster pump | Q=2T/h H=30m SUS304 | 1set |
12 | EDI Precision devices | 20″×5 | 1set |
13 | EDI Device | EDI Module | 1set |
EDI Power | 1set | ||
EDI flow switch | 2set | ||
14 | Storage EDIpure water tank | V=1m3 SUS304 | 1set |
Liquid level Sensors | 1set | ||
15 | UV sterilization device | UV Sterilizers Wavelength 265 Nm | 1set |
16 | Membrane filter | 20″×1 | 1set |
20” 0.22um Folded filter core | 1set | ||
17 | CIP | Online model | 1set |
Medicine washing pump | Q=2m3/hH=30m SUS304 | 1set | |
Cleaning water tank | PE-500L | 1set | |
Cleaning filters | 20″×3 | 1set | |
Cleaning accessories | DN20-25 | 1set | |
18 | Electric control | Air switch | 1set |
Contactor | 1set | ||
Liquid level controller | 1set | ||
Thermal overload relays | 1set | ||
Press switch | 1set | ||
Conductivity meter | 1set | ||
Wires and cables, Terminal | 1set | ||
19 | Other parts | Pipelines,valves, distribution | 1set |
Why need to provide the source water quality report?
1.The source water quality report can help engineers better understand the parameters of various indicators n the raw water, like the amount of all kinds of ions, bacteria, etc. Provide feasibility solution based on various parameter of raw water.
2.TDS(Total dissolved solid) and residual chlorine value is very import. before designing the proposal, engineers select high different pressure pumps with different pressures based on TDS value to make sure that the system can produce the clean water normally. Select the appropriate stainless steel material based on the residual chlorine to avoid the water leakage caused by corrosion.
3.From water analysis report can see the iron and manganese, turbidity, bacteria whether exceed the standard. Engineers can design the process flow chart and solution which best fit the demand to help reduce unnecessary expense which can help customers save the cost.
4.Engineers design the Ionized water treatment plant suitable proposal based on raw water quality report and product water purpose/standard which can operate normally and best fit the customer demand.
BTW: If source water is Municipal tap water or clean reservoir water or spring water no need report.
But please inform us the water characteristic.