welcome to Haiyuan water treatment Co. Ltd English|Spainsh|Online message

Remove Iron Manganese from well water

Time:2020-10-10 19:37:53

Remove Iron Manganese from well water

1.Why need remove Iron Manganese from Well Water?

(1)Sources of Iron and Manganese

Natural sources of iron and manganese are common in wells where the water has been in contact with rock for a longer time.  Iron and manganese often occur together in groundwater but manganese usually occurs in much lower concentrations than iron.The secondary drinking water standard set by the U.S. Environmental Protection Agency (EPA) for iron and manganese is 0.3 mg/l and 0.05 mg/l, respectively.

 

Both iron and manganese are readily apparent in drinking water supplies. Both impart a strong metallic taste to the water and both cause staining. Water coming from wells and springs with high iron or manganese may appear colorless initially but orange-brown (iron) or black (manganese) stains or particles quickly appear as the water is exposed to oxygen.

 

(2)Remove Iron Manganese is necessary to human health

1)Long-term excessive intake of manganese in the human body can cause chronic poisoning; in some areas, excessive manganese in water may be one of the causes of certain endemic diseases. Although iron in groundwater has little effect on human health, it cannot exceed a certain level. If the iron content in the water is greater than 0.3mg/L, Fe(OH)3 will precipitate due to oxidation of Fe2+ by air, and the water will become turbid; when it exceeds 1mg/L, the water will smell of iron. Manganese also often exists in a divalent form.

2)The oxidation rate of divalent manganese dissolved in water is very slow, so it generally does not make the water become muddy quickly, but after it precipitates, it can increase the chroma of the water, and its coloring ability is several times higher than that of iron. Sanitary utensils have a strong ability to contaminate. When the content of manganese exceeds 0.3mg/L, it can make the water smell bad.

When the concentration of manganese exceeds the binding capacity of hemoglobin, precipitation will be formed, causing metabolic acidosis in the body, causing tumor enlargement, liver damage and inducing diabetes. Physiological toxicity is more serious than iron.

3)Studies have shown that absorbing 0.5~0.6g/kg body weight of manganese can prevent its bone development. Some scholars believe that certain endemic diseases are related to water containing manganese all year round. Recent studies have found that excessive iron and manganese are about to damage the inner wall of arteries and myocardium, forming atherosclerotic plaques, resulting in coronary artery diameter and coronary heart disease.

 

2.Remove Iron Manganese from well water Product Description

We will customize the water treatment process according to the needs of customers

Drinking water treatment common process:

Suitable for river water/ tap water/ spring water/ well water/etc.

 Well water self-priming pump → aeration device → sedimentation tank → raw water booster pump → iron and manganese removal device → activated carbon filter →Security filter→RO  system →permeat tank→ water purification pool → water pointding, bubbling, or stripping the gas from the water.

 1. Aeration device The well water is pressurized by the self-priming pump and then enters the aeration device. It is mainly to allow the well water to fully contact the oxygen in the air; use the oxidation method to oxidize the low-valent iron ions and low-valent manganese ions in the water into The process of rapid precipitation of high-valent iron ions and high-valent manganese ions.

 2. The well water after oxygen aeration in the sedimentation tank reaches the sedimentation tank for precipitation. (It mainly acts as a buffer, so that the water has enough time to settle)

 3.The principle of RO water treatment system is that raw water passes through reverse osmosis membrane under high pressure, and the solvent in water diffuses from low concentration to high concentration to achieve the purpose of separation, purification and concentration. Reverse osmosis water treatment system can remove bacteria, viruses, colloid, organic matter and more than 99% soluble salts in water. The equipment has the characteristics of low operation cost, simple operation, high automation degree and stable effluent quality. Compared with other traditional water treatment methods, it has obvious advantages and is widely used in water treatment related industries.


3.Sales example:Remove Iron Manganese from well water

Remove Iron And Manganese from Well Water As Drinking Water

This is a guest from Norway. The water in his villa's well exceeds the standard of iron and manganese.

Raw Water Quality borehole water TDS 65PPM,Iron and manganese is over proof.

   Remove Iron Manganese RO water treatment plant flow chart/process:

Source water tank →Feed water pump → Iron Mn remove filter→ Sand filter →Carbon filter →Security filter→RO  system →permeat tank→UV→use point

    Example parameters of 1000L/hr Remove Iron Manganese RO water treatment plant

Items

Specification

unit

Feed water tank

2T

1 set

Feed water pump

CHL2-40/0.75KW

Type: centrifugal pump   

Material:SS304

Regulating valve, checking valve, etc.

1 set

Iron Mn remove filter 

Dimension:Φ325×1350(mm) 

 Auto Control valve: F67P

Manganese sand:  125kg

1 set

Sand  filter 

Dimension:Φ325×1350(mm) 

 Auto Control valve: F67P

Manganese sand:  125kg

1 set

Carbon filter

Dimension:Φ325×1350(mm) 

Auto Control valve: F67P

Quartz Sand:  40kg

1 set

Security filter

Dimension: Φ230×500*3

Housing:SS304,20”

1 set

High pressure pump

CDLS2-11 /1.1KW

Type: centrifugal pump

Material: SS304

Regulating valve, checking valve, etc.

1 set

RO skid       

Design temperature:25 

RO membrane: LP2148040  4piece

Spec4040

MaterialAromatic polyamide   

RO membrane housing

Material: FRP300PSI

Spec: 4040, 4 pcs

AccessoriesValves ,Flow rate, pressure gauge, etc.

RO skid frame: SS304

1 unit

UV sterilizer

 HY-UV 18w

1 unit

 Piping, valves, bends.

Low pressure parts: food stage UPVC

High pressure parts: PPR (more anti-corrosion for salty water)

 A lot

Instruments

Pressure gauges:

1.Discharge of all pumps,

2.Filters-inlet&outlet

3.RO –inlet&reject

Level switch: for source tank and clean tank.

Flow meter: RO concentrated water and permeated water

Online monitor conductivity/TDS meter

Press switch: Low&high pressure switch

 A lot

Full control for electrical controller system

AC contactor, time relay, insurance etc electrical components, electric cabinet, Wire and cable.

Power& control cables

Instrument cables for the instrumentation items

 A lot

 

4.Similar photos:Remove Iron Manganese from well water plant

 图片1.png

5.Before and after service for Remove Iron Manganese from well water treatment plant:

1. To provide oversea service to site help client installation.

2.We are the manufacturer not trader. You can find us solve any problem by online technical team.

3.The Advanced Water Treatment Engineer Certificate issued by The National Professional Center.

4.Professional welded engineer and design engineer and got the certification.

5.All the plant make as per ISO9001 Quality Management System Certificate and SGS Certificate sign.

6. All the plant have been finish complete assemble and testing by Ultrasonic wave detector.

7. The punctual delivery of goods, quality and quantity guaranteed.

8. Reasonable price and good service.

9.We have ourselves brand “JISHUI”. And technical patent.

 

6.Water treatment plant to remove Iron Manganese from Well Water,

we need below information so that we can make the correct design proposal.

1. Where is the source water from?(Better have water quality analysis report)

2. After treated water. What is the purpose?

3. How many liter water per hour?

4. Power is 380V/50hz or 60hz?

5. User need any Europe/USA brand or accept equal quality Chinese brand?

6. Any other detail requirement let us know.

Please let us know as much information as possible so that we can make the best plan for you.

7.More inquiries regarding Water treatment plant to remove Iron Manganese from Well Water

Please add: Whatsapp: +86 1353283 6525

Or send Email : sales@seawaterroplants.com


Prev: Iron and manganese removal filter - Angolan customer

Next:Containerised Seawater desalination plant 10TPH - Algerian customer

©2121 HY water, Ltd All Rights reserved.
Industrial & drinking Reverse osmosis water purification system,Seawater desalinaton plant in Africa, Asia, Europe, South America, Australia |Made in China by Haiyuan. an ISO9001:2019 Certified Company Add: Xiansha Gaobu Town,Dongguan city,Guangdong,China|+86(769)88706055| Email:sales@seawaterroplants.com