Wechat/Whatsapp:
+8613798883773
Time:2020-10-10 19:37:53
Remove Iron Manganese from well water 1.Why need remove Iron Manganese from Well Water? (1)Sources of Iron and Manganese Natural sources of iron and manganese are common in wells where the water has been in contact with rock for a longer time. Iron and manganese often occur together in groundwater but manganese usually occurs in much lower concentrations than iron.The secondary drinking water standard set by the U.S. Environmental Protection Agency (EPA) for iron and manganese is 0.3 mg/l and 0.05 mg/l, respectively. Both iron and manganese are readily apparent in drinking water supplies. Both impart a strong metallic taste to the water and both cause staining. Water coming from wells and springs with high iron or manganese may appear colorless initially but orange-brown (iron) or black (manganese) stains or particles quickly appear as the water is exposed to oxygen. (2)Remove Iron Manganese is necessary to human health 1)Long-term excessive intake of manganese in the human body can cause chronic poisoning; in some areas, excessive manganese in water may be one of the causes of certain endemic diseases. Although iron in groundwater has little effect on human health, it cannot exceed a certain level. If the iron content in the water is greater than 0.3mg/L, Fe(OH)3 will precipitate due to oxidation of Fe2+ by air, and the water will become turbid; when it exceeds 1mg/L, the water will smell of iron. Manganese also often exists in a divalent form. 2)The oxidation rate of divalent manganese dissolved in water is very slow, so it generally does not make the water become muddy quickly, but after it precipitates, it can increase the chroma of the water, and its coloring ability is several times higher than that of iron. Sanitary utensils have a strong ability to contaminate. When the content of manganese exceeds 0.3mg/L, it can make the water smell bad. When the concentration of manganese exceeds the binding capacity of hemoglobin, precipitation will be formed, causing metabolic acidosis in the body, causing tumor enlargement, liver damage and inducing diabetes. Physiological toxicity is more serious than iron. 3)Studies have shown that absorbing 0.5~0.6g/kg body weight of manganese can prevent its bone development. Some scholars believe that certain endemic diseases are related to water containing manganese all year round. Recent studies have found that excessive iron and manganese are about to damage the inner wall of arteries and myocardium, forming atherosclerotic plaques, resulting in coronary artery diameter and coronary heart disease. 2.Remove Iron Manganese from well water Product Description We will customize the water treatment process according to the needs of customers Drinking water treatment common process: Suitable for river water/ tap water/ spring water/ well water/etc. Well water self-priming pump → aeration device → sedimentation tank → raw water booster pump → iron and manganese removal device → activated carbon filter →Security filter→RO system →permeat tank→ water purification pool → water pointding, bubbling, or stripping the gas from the water. 1. Aeration device The well water is pressurized by the self-priming pump and then enters the aeration device. It is mainly to allow the well water to fully contact the oxygen in the air; use the oxidation method to oxidize the low-valent iron ions and low-valent manganese ions in the water into The process of rapid precipitation of high-valent iron ions and high-valent manganese ions. 2. The well water after oxygen aeration in the sedimentation tank reaches the sedimentation tank for precipitation. (It mainly acts as a buffer, so that the water has enough time to settle) 3.The principle of RO water treatment system is that raw water passes through reverse osmosis membrane under high pressure, and the solvent in water diffuses from low concentration to high concentration to achieve the purpose of separation, purification and concentration. Reverse osmosis water treatment system can remove bacteria, viruses, colloid, organic matter and more than 99% soluble salts in water. The equipment has the characteristics of low operation cost, simple operation, high automation degree and stable effluent quality. Compared with other traditional water treatment methods, it has obvious advantages and is widely used in water treatment related industries. 3.Sales example:Remove Iron Manganese from well water Remove Iron And Manganese from Well Water As Drinking Water This is a guest from Norway. The water in his villa's well exceeds the standard of iron and manganese. Raw Water Quality borehole water TDS 65PPM,Iron and manganese is over proof. Remove Iron Manganese RO water treatment plant flow chart/process: Source water tank →Feed water pump → Iron Mn remove filter→ Sand filter →Carbon filter →Security filter→RO system →permeat tank→UV→use point Example parameters of 1000L/hr Remove Iron Manganese RO water treatment plant Items Specification unit Feed water tank 2T 1 set Feed water pump CHL2-40/0.75KW Type: centrifugal pump Material:SS304 Regulating valve, checking valve, etc. 1 set Iron Mn remove filter Dimension:Φ325×1350(mm) Auto Control valve: F67P Manganese sand: 125kg 1 set Sand filter Dimension:Φ325×1350(mm) Auto Control valve: F67P Manganese sand: 125kg 1 set Carbon filter Dimension:Φ325×1350(mm) Auto Control valve: F67P Quartz Sand: 40kg 1 set Security filter Dimension: Φ230×500*3 Housing:SS304,20” 1 set High pressure pump CDLS2-11 /1.1KW Type: centrifugal pump Material: SS304 Regulating valve, checking valve, etc. 1 set RO skid Design temperature:25℃ RO membrane: LP2148040 4piece Spec:4040 Material:Aromatic polyamide RO membrane housing Material: FRP(300PSI) Spec: 4040, 4 pcs Accessories:Valves ,Flow rate, pressure gauge, etc. RO skid frame: SS304 1 unit UV sterilizer HY-UV 18w 1 unit Piping, valves, bends. Low pressure parts: food stage UPVC High pressure parts: PPR (more anti-corrosion for salty water) A lot Instruments Pressure gauges: 1.Discharge of all pumps, 2.Filters-inlet&outlet 3.RO –inlet&reject Level switch: for source tank and clean tank. Flow meter: RO concentrated water and permeated water Online monitor conductivity/TDS meter Press switch: Low&high pressure switch A lot Full control for electrical controller system AC contactor, time relay, insurance etc electrical components, electric cabinet, Wire and cable. Power& control cables Instrument cables for the instrumentation items A lot 4.Similar photos:Remove Iron Manganese from well water plant 5.Before and after service for Remove Iron Manganese from well water treatment plant: 1. To provide oversea service to site help client installation. 2.We are the manufacturer not trader. You can find us solve any problem by online technical team. 3.The Advanced Water Treatment Engineer Certificate issued by The National Professional Center. 4.Professional welded engineer and design engineer and got the certification. 5.All the plant make as per ISO9001 Quality Management System Certificate and SGS Certificate sign. 6. All the plant have been finish complete assemble and testing by Ultrasonic wave detector. 7. The punctual delivery of goods, quality and quantity guaranteed. 8. Reasonable price and good service. 9.We have ourselves brand “JISHUI”. And technical patent. 6.Water treatment plant to remove Iron Manganese from Well Water, we need below information so that we can make the correct design proposal. 1. Where is the source water from?(Better have water quality analysis report) 2. After treated water. What is the purpose? 3. How many liter water per hour? 4. Power is 380V/50hz or 60hz? 5. User need any Europe/USA brand or accept equal quality Chinese brand? 6. Any other detail requirement let us know. Please let us know as much information as possible so that we can make the best plan for you. 7.More inquiries regarding Water treatment plant to remove Iron Manganese from Well Water Please add: Whatsapp: +86 1353283 6525 Or send Email : sales@seawaterroplants.com