Wechat/Whatsapp:
+8613798883773
HYWATER UF | RO For Drinking
Water treatment systems|Water treatment systems reverse osmosis systems 1000LPH A.Water treatment systems parameter Model HYRO-1000 Production capacity 1000Liter per hour Total power 1.65KW Raw water pump CHL2-40 /0.55KW Quartz sand filter, carbon filter Φ325 × 1350, FRP or stainless steel Security filter 20 "× 5μm ,3 core , stainless steel High-pressure pump CDLS2-11 / 1.1KW 1 set Nanfang RO membrane Membrane LCLE-4040 4 PCS USA DOW Membrane housing 4040-4pcs , stainless steel Quartz sand 125kg Activated carbon 40kg Size 2000X800X1750mm B.Water treatment systems reverse osmosis systems process Raw water pump→ Quartz sand filter→ activated carbon filter→ (water softener)→security filter → high pressure pump →Reverse osmosis system→ (ozone generator)→ purified water tank (The client should supply all the water tank ) C.Water treatment systems application field design based on different requirement 1)The treated water can used for shower,cooking, drinking, washing,food, beverage, bottled drinking water, sachet/pouch packing pure drinking water treatment, also use for domestic ,poultry and irrigation. 2)Chemical industry, pharmaceutical industry pure water treatment 3)Electronic industry, semiconductor industry ultrapure water treatment 4)Electroplating 5)Cosmetic products, car battery, liquid fertilizer production pure water treatment 6)Edible cube ice, tube ice etc. 7)School, hotel, hospital, laboratory, surface treatment, hydraulic test, industrial boiler, power station boiler, high pressure boiler water treatment D.Water treatment systems reverse osmosis systems has the following excellent characteristics: 1) Water treatment systems reverse osmosis systems parts and components are imported products with advanced technology 2) Reverse osmosis systems reliable quality, high degree of integration, easy to expand, increase the number of membranes to increase processing capacity 3) Water treatment system high degree of automation, self-stop immediately in case of failure, with automatic protection function 4) Water treatment systems reverse osmosis systems high desalination rate, up to 98% 5)Reverse osmosis systems low energy consumption and low operating cost 6) Water treatment system high water utilization rate 7) Water treatment systems reverse osmosis systems reasonable structure, less floor space, saving more than 30% space than conventional methods 8) Reverse osmosis systems advanced membrane protection system, when the equipment is shut down, desalinated water can automatically clean the membrane surface contaminants, prolong membrane life, the system has no wearing parts, does not require a lot of maintenance costs, and the long-term effective equipment is designed with membrane cleaning system and Anti-scale system E.Water treatment systems more different product model for your reference Model Capacity Inlet Outlet Rated Power Demension Quotation (EXW USD) Ship Weight JSPS-0.25T 1500GPD(0.25m3/h) 1/2" 1/2" 1.65 180*90*170 1880-2179 200 JSPS-0.5T 3000GPD(0.5m3/h) 3/4" 1/2" 1.65 180*90*170 2183-2494 220 JSPS-0.75T 3000GPD(0.5m3/h) 3/4" 1/2" 1.65 180*90*170 2547-2872 300 JSPS-1T 6000GPD(1.0m3/h) 1" 3/4" 1.65 190*100*210 2982-3326 350 JSPS-1.5T 9000GPD(1.5m3/h) 1" 3/4" 2.3 190*100*210 3711-4238 370 JSPS-2T 12000GPD(2.0m3/h) 1-1/4" 1" 3 230*100*210 4612-5139 450 JSPS-2.5T 15000GPD(2.5m3/h) 1-1/4" 1" 4 230*100*210 5442-6492 520 JSPS-3T 18000GPD(3.0m3/h) 1-1/2" 1" 5.5 245*100*210 7526-8399 610 JSPS-4T 24000GPD(4.0m3/h) 1-1/2" 1-1/4" 7 275*100*210 8970-13127 740 JSPS-5T 30000GPD(5.0m3/h) 1-1/2" 1-1/4" 7 300*100*210 10308-14411 880 Why need to provide the source water quality report? 1.The source water quality report can help engineers better understand the parameters of various indicators n the raw water, like the amount of all kinds of ions, bacteria, etc. Provide feasibility solution based on various parameter of raw water. 2. TDS(Total dissolved solid) and residual chlorine value is very import. before designing the proposal, engineers select high different pressure pumps with different pressures based on TDS value to make sure that the system can produce the clean water normally. Select the appropriate stainless steel material based on the residual chlorine to avoid the water leakage caused by corrosion. 3.From water analysis report can see the iron and manganese, turbidity, bacteria whether exceed the standard. Engineers can design the process flow chart and solution which best fit the demand to help reduce unnecessary expense which can help customers save the cost. 4. Engineers design the Water treatment systems suitable proposal based on raw water quality report and product water purpose/standard which can operate normally and best fit the customer demand. BTW: If source water is Municipal tap water or clean reservoir water or spring water no need report. But please inform us the water characteristic. Water treatment systems based on different capacity and treated water standard or purpose. we will supply the Optimization solution for client. Water treatment systems |Water treatment systems reverse osmosis systems more related to information (different source water, capacity, voltage), please feel free to contact us! Email: Sales003@water-sy.com Mob&WhatsApp&WhatChat: +8618825874379 or +8613922972795 We will provide high-quality, all-round comprehensive professional services for project consulting, system design, manufacturing, installation and commissioning, personnel training, etc. Industrial portable water purification system 50TPH
Pipe(Inch)
Pipe(Inch)
(KW)
L*W*H (CM)
(Kg)