Wechat/Whatsapp:
+8613798883773
HYWATER UF | RO For Drinking
Desalination brackish water|Brackish water ro system|Brackish water process reverse osmosis ro 20TPH for irrigation Fresh water is needed for irrigation water in Africa and the Middle East, and fresh water resources are increasingly scarce. The vast majority of professional growers have exploited drilling water and groundwater for irrigation. Most of these ground water and well water are polluted, and the water contains high salt content. Suitable for irrigation, then brackish water (surface water and groundwater with a salt content of 1500 ~ 5000mg / L) must be processed into fresh water by reverse osmosis before it can be used for irrigation. A.Desalination brackish water introduction 1. Source water: TDS8000mg/l 4. Plant size: L13×W1.5×H2.6(m) B.Brackish water ro system control method: Whole system use full automatically control model, both model can be exchanged accordingly. Sand filter and Carbon filter with auto and manual back flush.The RO system automatic flushing at each start-up and shutdown. High water level auto stop, low water level auto start.Pump protected without water. Protected when no power, poor power, larger electrical current, leakage, short circuit. C.Brackish water process reverse osmosis flow chart Feed water tank-->Feed water pump-->Multimedia filter-->PP filter-->High pressure pump-->RO system-->RO tank-->Cleanig system(alternative)-->Product water tank D.Desalination brackish water analysis about process Brackish water from the water pump into the quartz sand (multi-media filter) and activated carbon filtration system filtration. Filtered water after water quality reduction, PH adjustment and scale inhibitor added after the access to the precision and security filtration system, filtered low pressure brackish water all the way into the high-pressure pump pressure, the other way into the pressure exchange energy recovery device, after pressurized pump pressurized with high pressure pump into the reverse osmosis membrane reactor system. High-pressure brackish water in the membrane reactor under the treatment of the formation of fresh water through the membrane after water quality adjustment into the fresh water tank storage. The rest of the high pressure concentrated water enters the pressure exchange energy recovery unit to recover the energy after discharge. E.Brackish water ro system product list Items Quantity Remark Feed water tank 1set User prepare Material:PE/SUS Volume:40m³ Level switch 1pc HY/CHINA Feed water pump Groundfors/Denmark Model:CR64-2-1/11KW 1set Q=40m³/hr,H=48m Material:SUS304 Regulating valve, checking valve, etc. 1 lot Sand filter HY/CHINA Vessel 2sets Model: Φ1200×2400mm Material: FRP Media:Quartz sand 4000kg(2000kg for each) Control valve:Auto valve-F112B 2sets Valve fittings,matching 1 lot Anti-scale dosing unit SEKO/Italy Dosing pump: KCL-635 1set Dosing tank: 100L Valve fittings, matching 1 lot Micron cartridge filter HY/CHINA Vessel: UPVC 3sets Size:Φ40" Filter element:PP 27pcs(9pcs for each) High pressure pump Groundfors/Denmark Model:CR45-10/37KW 1set Q=40m³/hr, H=222m, P=21.39bar Material:SUS304 Regulating valve, checking valve, etc. 1 lot RO main system Design temperature:25℃,recovery rate:60% RO membrane: TM720D-400 24pcs Toary/Japan Spec:8040 Material:Aromatic polyamide RO membrane housing 4pcs HY/CHINA Material: FRP(450PSI) Spec: 8040X6 Accessories: valves, fittings, etc. 1 lot Electrical control system HY/CHINA Automatic control 1item Electric cabinet 1 set Circuit breaker, contactor, thermal relay, etc. 1 lot Schneider/France Electrical accessories 1 lot Pipes HY/CHINA Low pressure parts: Food stages UPVC 1 lot High pressure parts: Food stages SS316 1 lot Frame HY/CHINA Frame 1 lot Material:carbon steel Product water tank 1 set User prepare Material:PE/SUS Volume:24m3 Level switch 1 pc HY/CHINA In order to send you correct information please tell me below information 1. How many liters outlet water per hour do you require?(500L/H,1000L/H, 50m3/hr,etc.) 2. Where is the source water from? (Eg,well water/borehole water, river water. etc.)- Do you have water analysis result or know the water quality? (The TDS=total dissolved solid, Fe, Mg, Hardness etc. whether over proof etc). 3. After treated, The water meet WHO drinking water standard, or as per bottle water standard or other industrial purpose? 4. Your local power is 380V/50hz 3phase or 380V/60Hz 3 phase, 440/60hz 3 phase or other voltage? BTW: If source water is Municipal tap water or clean reservoir water or spring water no need report. But please inform us the water characteristic. More inquiries related to Desalination brackish water|Brackish water ro system|Brackish water process reverse osmosis ro (Different source water and capacity with different design),please feel free to contact us! E-mail: sales003@water-sy.com Wechat(WhatsApp): 008618825874379/008613922972795 Brackish water purification system 2TPH
2. System working Voltage/Power: 380V/50HZ 3phase 48KW
3. Outlet Purified water standard: Meet WHO drinking standard