Wechat/Whatsapp:
+8613798883773
DM water plant price,DM water plant,dm plant,dm plant price
A: DM water plant product description
· Demineralized water,Desalted water generally refers to the finished water obtained by removing impurities in water such as suspended solids, colloids and inorganic cations and anions using various water treatment processes. Desalination does not mean that all salts in the water have been removed. Depending on the application, demineralization is allowed to contain trace impurities. The fewer impurities in the brine, the higher the water purity. Demineralized water contains little or no minerals. This can be done by distillation, reverse osmosis, ion exchange, or a combination of these methods.
· The reverse osmosis method uses a reverse osmosis membrane and uses the external pressure (such as the pressure of a water pump) as a driving force to force water molecules in the raw water to pass through the membrane selectively to achieve the purpose of removing salts and impurities, so that the water Get purified. This method is easy to operate, has a large water output and is non-polluting, and has been widely used in recent years.
DM water plant Usually the Process have 4 process . It base on the feed water quality and output water quality:
1.Source water tank →Pretreatment parts→ Single RO system→ RO tank→EDI system →DM water→10MΩ/cm outlet water.
2.Source water tank →Pretreatment parts→ Double RO system→Double RO tank→EDI system →DM water→15MΩ/cm outlet water.
3.Source water tank →Pretreatment parts→ Double RO system→Double RO tank→EDI system →Polish resin filter→ 18 MΩ/cm outlet water.
4.Source water tank →Pretreatment parts→ Cation resin →Anion resin →Middle tank→Mixed bed →DM water→15MΩ/cm outlet water.
B:DM water plant design basis
Raw water :brackish water with TDS 9000 ppm
Out water: resistivity 15MΩ/cm
Production capacity: 1000 litres/hr
Product water : for drinking water
Voltage and frequency: 220V、380V、415V、440V、50-60HZ
C: DM plant control method
Whole system use full automatically control model, both model can be exchanged accordingly. Sand filter with auto and manual back flush.The RO system automatic flushing at each start-up and shutdown. High water level auto stop, low water level auto start.Pump protected without water.Protected when no power, poor power, larger electrical current, leakage, short circuit.
D: DM water plant Process Flow
Source tank →Feed water pump→ Muti-media filter(sands filter)→ Active carbon filter→ Water softener(or inhibitor dosing)→Cartridge/Security/Micro filter→High-pressure/Centrifugal pump→ Reverse Osmosis system→ RO purified tank→EDI system →DM water→15MΩ/cm outlet water
E: Why need to provide the source water quality report?
1.The source water quality report can help engineers better understand the parameters of various indicators n the raw water, like the amount of all kinds of ions, bacteria, etc. Provide feasibility solution based on various parameter of raw water.
2. TDS(Total dissolved solid) and residual chlorine value is very import. before designing the proposal, engineers select high different pressure pumps with different pressures based on TDS value to make sure that the system can produce the clean water normally. Select the appropriate stainless steel material based on the residual chlorine to avoid the water leakage caused by corrosion.
3.From water analysis report can see the iron and manganese, turbidity, bacteria whether exceed the standard. Engineers can design the process flow chart and solution which best fit the demand to help reduce unnecessary expense which can help customers save the cost.
4. Engineers design the DM water plant suitable proposal based on raw water quality report and product water purpose/standard which can operate normally and best fit the customer demand.
BTW: If source water is municipal tap water or clean reservoir water or spring water no need report.
But please inform us the water characteristic.
Please contact us!
Email: Sales@seawaterroplants.com
Mob&WhatsApp&WhatChat: +8613922972795
DM water plant based on different capacity and treated water standard or purpose, we will supply the Optimization solution for client.