Wechat/Whatsapp:
+8613798883773
HYWATER UF | RO For Drinking
Brackish water ro system in water treatment|Brackish water treatment plant|Brackish water treatment 1TPH for irrigation A.Brackish water ro system in water treatment introduction Fresh water is needed for irrigation water in Africa and the Middle East, and fresh water resources are increasingly scarce. The vast majority of professional growers have exploited drilling water and groundwater for irrigation. Most of these ground water and well water are polluted, and the water contains high salt content. Suitable for irrigation, then brackish water (surface water and groundwater with a salt content of 1500 ~ 5000mg / L) must be processed into fresh water by reverse osmosis before it can be used for irrigation. B.Brackish water treatment plant product list Item Name Specification Qty 1 Source water tank 1500L 1 set 2 Feed water pump CHL2-40/.55KW 1 set 3 sand filter vessel Φ325x1350 1 set Silica Sands 2-4,1-2,0.5-1.get rid of turbidity, suspended matter, organic matters, colloid ,ect. 125 kg Sand filter control F71B 1 set 4 Active carbon filter vessel Φ325x1350 1 set Active Carbon 8-16.Remove the color, free chloride, organic matter, 40 Kg Carbon filter control F71B 1 set 5 Antiscalant dosing device Dosing pump with dosing tank 1 Set 6 Security filter 20 inch big blue 1 set 7 High pressure pump CDLS2-22/2.2KW 1 set 8 RO system RO membrane 4040 4pcs, membrance vessel 4 pieces 1 unit C.Brackish water treatment flow chart Raw water→ raw water pump→quartz sand filter →activated carbon filter→chemical dosing system→security filter→high pressure pump→ro system→water supply point D.Brackish water ro system in water treatment analysis about process Brackish water from the water pump into the quartz sand (multi-media filter) and activated carbon filtration system filtration. Filtered water after water quality reduction, PH adjustment and scale inhibitor added after the access to the precision and security filtration system, filtered low pressure brackish water all the way into the high-pressure pump pressure, the other way into the pressure exchange energy recovery device, after pressurized pump pressurized with high pressure pump into the reverse osmosis membrane reactor system. High-pressure brackish water in the membrane reactor under the treatment of the formation of fresh water through the membrane after water quality adjustment into the fresh water tank storage. The rest of the high pressure concentrated water enters the pressure exchange energy recovery unit to recover the energy after discharge. Difference raw water quality will used difference solution Our main product is RO system water machine what we can do is to help changing such as seawater, brackish water,underground water and tap water atc...into domestic water, irrigation, direct drinking or bottle drinking(pure/mineral/alkaline water), industrial water: boiler water, hospital usages, beverage usages atc... 1.Homes and Villas 2.Hotels/Hospitals 3.Commercial Complexes 4.Kindney Dialysis Unit 5.Poultry Farms 6.Food and beverages industry 7.Bottled drinking water plants 8.Cooling tower /Boiler feed water 9.Agricultural irrigation F.Our service 1.All the machine can be warranted for one year. 2.Can offer the engineer to overseas to offer the training. 3.Offer the technical support all the time and we pay great attention to timeliness for the convenience of customers; 4.Every machine before shipped will be test for some time to ensure without any problems. 5.Good production capacity, will arrange the shipment on time! 6.Professional team, tell us what you needs, we will quickly provide a suitable solution with you. In order to send you correct information please tell me below information 1. How many liters outlet water per hour do you require?(500L/H,1000L/H, 50m3/hr,etc.) 2. Where is the source water from? (Eg,well water/borehole water, river water. etc.)- Do you have water analysis result or know the water quality? (The TDS=total dissolved solid, Fe, Mg, Hardness etc. whether over proof etc). 3. After treated, The water meet WHO drinking water standard, or as per bottle water standard or other industrial purpose? 4. Your local power is 380V/50hz 3phase or 380V/60Hz 3 phase, 440/60hz 3 phase or other voltage? BTW: If source water is Municipal tap water or clean reservoir water or spring water no need report. But please inform us the water characteristic. Brackish water ro system in water treatment based on different capacity and treated water standard or purpose. we will supply the Optimization solution for client. Brackish water ro system in water treatment|Brackish water treatment plant|Brackish water treatment more related to information (different source water, capacity, voltage), please feel free to contact us! Email: Sales@seawaterroplants.com Mob&WhatsApp&WhatChat: +8618825874379 or +8613922972795 We will provide high-quality, all-round comprehensive professional services for project consulting, system design, manufacturing, installation and commissioning, personnel training, etc.
valve
harmful matter ,ect
valveE.Brackish water treatment plant application: