A: Industrial water deionized description
Deionized water: Deionized water prepared by non-heat treatment using ion exchange method, reverse osmosis method, mixed bed method, EDI electric desalination method. That is, deionized water refers to pure water after removing impurities in the form of ions. Deionized water is commonly referred to as "ultra-pure water" or "18 megohm water" in the semiconductor industry.
B: Deionized water system price normally parameters
WHO water or Brackish water :TDS <500
Out water: Resistivity ≥10MΩ.cm
Operating Pressure: < 30 psi
Maximum Recovery: 98% - 100%
Desalination rate: 99%
Operating Temperature: 5-35 ºC
Minimum Inlet Pressure: 30 psi
Design Temperature: 25 ºC
C:Industrial deionized water processe flow
Raw water → Multi-media filter → Activated carbon filter → Precision filter → Reverse osmosis equipment → Electric deionization (EDI) → Deionized water tank → Deionized water pump → Rear security filter → Water point
At present, the processes of deionized water system in the industry mainly include the following:
1) Reverse osmosis;
2) Reverse osmosis + mixed bed ion exchange
3)Reverse osmosis + Double bed(cation resin+anion resin)
3) Reverse osmosis + EDI
4) Multiple beds + mixed bed ion exchange
Above four difference deionized water unit and the price will be the difference.
D: Example:Deionized water system configuration list 1000L/hr
NO | The product name | Specifications | Quantity |
1 | The feed water tank | V=2m3 304 | 1set |
Liquid level Sensors | 1set | ||
2 | Raw water pump | Q=4m3/h H=40m SUS304 | 1set |
3 | Multi-media filter vessel | Model:1665 | 1set |
Size: Φ400×H1500mm | |||
Tank Material: FRP | |||
Control valve | 1set | ||
Multi-media filter: quartz sand | 200kg | ||
Pressure gauge:1MPA | 1set | ||
4 | Active carbon filter
| Model:1665 | 1set |
Size: Φ400×H1500mm | |||
Tank Material: FRP | |||
Control valve | 1set | ||
Multi-media filter: Active carbon | 100kg | ||
Pressure gauge:1MPA | 1set | ||
5 | Cartridge filter& PP sediment filter | Size: 195*500*5 | 1set |
Material Stainless steel | |||
5um PP elements 20″ | 5set | ||
6 | One-high press pump | Q=4m3/h H=130m SUS316 | 1set |
7 | One stage reverse osmosis system | Pressure vessel:4040×1 | 4set |
RO membrane:4040 | 4set | ||
Pure water flow meter | 1set | ||
Concentrated water flow meter | 1set | ||
Concentrated water control valve | 1set | ||
Pipe valves | 1set | ||
High and low pressure protection switch | 1set | ||
Check valve | 1set | ||
SUS316 | |||
Automatic cleaning valve | 1set | ||
Online monitoring of inlet conductivity of the water meter | 1set | ||
Online monitoring of production water conductivity meter | 1set | ||
Pressure gauge:0~0.7 | 2set | ||
Pressure gauge:0~2.5MPa | 2set | ||
Sampling valve | 1set | ||
8 | PH adjustable system | Burkert | 1set |
PE-40L | |||
9 | RO tank | V=1m3 SUS316L | 1set |
Liquid level Sensors | 1set | ||
10 | EDI Booster pump | Q=2m3/h H=30m | 1set |
11 | EDI Precision devices | 20″×5 | 1set |
12 | EDI Device | EDI Module | 1set |
EDI Power | 1set | ||
EDI flow switch | 2set | ||
13 | Storage EDIpure water tank | V=1m3 | 1set |
Liquid level Sensors | 1set | ||
14 | UV sterilization device | UV Sterilizers Wavelength 265 Nm | 1set |
15 | Membrane filter | 20″×5 | 1set |
20” 0.22um Folded filter core | 1set | ||
16 | CIP | Online model | 1set |
Medicine washing pump | Q=2m3/h H=30m | 1set | |
Cleaning water tank | PE | 1set | |
Cleaning filters | 20″×3 | 1set | |
Cleaning accessories | DN20 | 1set | |
17 | Electric control system | Air switch | 1set |
Contactor | 1set | ||
Liquid level controller | 1set | ||
Thermal overload relays | 1set | ||
Press switch | 1set | ||
Conductivity meter | 1set | ||
Wires and cables, Terminal | 1set | ||
18 | Other parts | Pipelines, valves, distribution | 1set |
Cation resin filter+anion resin filter
Why need to provide the source water quality report?
1.The source water quality report can help engineers better understand the parameters of various indicators n the raw water, like the amount of all kinds of ions, bacteria, etc. Provide feasibility solution based on various parameter of raw water.
2. TDS(Total dissolved solid) and residual chlorine value is very import. before designing the proposal, engineers select high different pressure pumps with different pressures based on TDS value to make sure that the system can produce the clean water normally. Select the appropriate stainless steel material based on the residual chlorine to avoid the water leakage caused by corrosion.
3.From water analysis report can see the iron and manganese, turbidity, bacteria whether exceed the standard. Engineers can design the process flow chart and solution which best fit the demand to help reduce unnecessary expense which can help customers save the cost.
4. Engineers design the deionized water system suitable proposal based on raw water quality report and product water purpose/standard which can operate normally and best fit the customer demand.